DAMPERS

JD – 3001

  • Extruded aluminium volume control damper with aerofoil type opposed blade doors controlled by P V C gears and operated by motor actuator.
  • The flanges are suitable to connect TDF flanged ducts.

JD – 3002

  • G I volume control damper with opposed blade doors controlled by P V C gears and operated by motor actuator.
  • The flanges are suitable to connect TDF flanged ducts

JD – 3003

  • Volume control damper with G I outer frame and extruded aluminium aerofoil doors of  opposed blade type controlled by P V C gears and manual operation.
  • The flanges are suitable to connect TDF flanged ducts.

JD – 3004

  • G I Fire damper with M S control links and connected with fusible links.
  • The flanges are suitable to connect TDF flanged ducts.

 

JD – 3005

  • G I Fire damper with M S control links and operated by motor actuator.
  • These fire damper having sleeves of different sizes to suit site conditions.
  • The flanges are suitable to connect TDF flanged ducts.

JD – 3006

  • G I Fire damper with M S control links and connected with fusible links.
  • These fire damper having sleeves of different sizes to suit site conditions.
  • The flanges are suitable to connect TDF flanged ducts.

JD – 3007

  • G I VCD for oval duct.

JD – 3008

  • Non Return Damper with G I outer frame and aluminium flaps.
  • The flanges are suitable to connect TDF flanged ducts.

JD – 3009

  • Volume control damper with Pre insulated forms for frame and extruded aluminium aerofoil doors of opposed blade type controlled by P V C gears and manual operation.
  • The flanges are suitable to connect TDF flanged ducts.

JD – 3010

  • External louvers, generally fitted at the outlet of exhaust fans ( non return type ).

JD – 3011

  • Butterfly dampers are made from G I sheets and are suitable for round ducts.

JD – 3012

  • Stream Split Damper (SPD) are made from GI sheets and are used along with grills in air outlet of supply air ducts.

JD – 3013

  • Extruded aluminium powder coated opposed blade collar damper for installing in duct collars

JD – 3014

  • GI opposed blade collar damper for diffusers (square). Finish black enamel paint

JD – 3015

  • GI opposed blade collar damper for grills (rectangular). Finish black enamel paint.

JD – 3016

  • Spigot (mixing box) connected to the top of supply air diffusers and the air is top entry.

JD – 3017

  • Butterfly type dampers for round collars.

JD – 3018

  • GI mixing box at the inlet of supply air diffusers.

JD – 3019

  • Adaptor to connect a diffuser of any neck size with the existing duct collar.

JD – 3020

  • G I duct connecting piece with TDF flanges.